{"id":479,"date":"2025-09-18T11:54:07","date_gmt":"2025-09-18T11:54:07","guid":{"rendered":"https:\/\/docs.qilowatt.eu\/docs\/solis-s6\/"},"modified":"2026-07-03T03:22:48","modified_gmt":"2026-07-03T03:22:48","password":"","slug":"solis-s6","status":"publish","type":"docs","link":"https:\/\/docs.qilowatt.eu\/en\/docs\/solis-s6\/","title":{"rendered":"Solis S6"},"content":{"rendered":"\n<h2 id=\"gspb_heading-id-gsbp-04748af\" class=\"gspb_heading gspb_heading-id-gsbp-04748af \">Introduction<\/h2>\n\n<div id=\"gspb_text-id-gsbp-5590435\" class=\"gspb_text gspb_text-id-gsbp-5590435 \">Solis S6 inverters can be connected to the Qilowatt system via Modbus communication. This guide explains the necessary preparations, RS485 wiring, inverter settings, and operating modes. <\/div>\n\n<h2 id=\"gspb_heading-id-gsbp-13b65a4\" class=\"gspb_heading gspb_heading-id-gsbp-13b65a4 \">Prerequisites<\/h2>\n\n<div id=\"gspb_text-id-gsbp-df57208\" class=\"gspb_text gspb_text-id-gsbp-df57208 \">\u2022 Inverter and battery firmware are updated (latest version must be used)<br\/>\u2022 A Modbus module is available<br\/>\u2022 Required tools and a communication cable (CAT5 or CAT6)<br\/>\u2022 A Qilowatt account has been created and the app is ready for adding devices \u2192 <a href=\"https:\/\/docs.qilowatt.eu\/en\/docs\/creating-a-user-account\/\">Creating a user account<\/a><\/div>\n\n<h2 id=\"gspb_heading-id-gsbp-c43af74\" class=\"gspb_heading gspb_heading-id-gsbp-c43af74 \">Step-by-step Guide<\/h2>\n\n<h3 id=\"gspb_heading-id-gsbp-75a5de1\" class=\"gspb_heading gspb_heading-id-gsbp-75a5de1 \">1. Preparation<\/h3>\n\n<div id=\"gspb_text-id-gsbp-aee772c\" class=\"gspb_text gspb_text-id-gsbp-aee772c \">\u2022 Update the <strong>inverter and battery firmware<\/strong> before connecting.<br\/>\u2022 Ensure the device has the <strong>latest firmware<\/strong>, since Qilowatt always relies on the newest Modbus protocol.<\/div>\n\n<h3 id=\"gspb_heading-id-gsbp-0566595\" class=\"gspb_heading gspb_heading-id-gsbp-0566595 \">2. RS485 connections<\/h3>\n\n<div id=\"gspb_text-id-gsbp-7dc33b9\" class=\"gspb_text gspb_text-id-gsbp-7dc33b9 \">\u2193 Solis S6 3-10kW HV; Solis S6 8-15kW LV \u2193<\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-cbc7b93\" id=\"gspb_image-id-gsbp-cbc7b93\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/photo_2025-11-10_13-28-31.jpg\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"955\" height=\"602\"><\/div>\n\n<div id=\"gspb_text-id-gsbp-46e2044\" class=\"gspb_text gspb_text-id-gsbp-46e2044 \">\u2193 Solis S6 12-20kW HV \u2193<\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-b833ab6\" id=\"gspb_image-id-gsbp-b833ab6\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/photo_2025-11-10_13-28-26.jpg\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"1007\" height=\"602\"><\/div>\n\n<div id=\"gspb_text-id-gsbp-2fe239a\" class=\"gspb_text gspb_text-id-gsbp-2fe239a \">Solis S6 30\u2013125 kW must be connected to the EMS port, not RS485. (If the battery is a Dyness BF100, the Qilowatt controller must be connected to the EMS port, the battery BMS cable to the BMS port, and the battery EMS cable to the RS485 port.) <\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-fab5353\" id=\"gspb_image-id-gsbp-fab5353\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/photo_2025-11-10_13-28-31.jpg\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"955\" height=\"602\"><\/div>\n\n<h3 id=\"gspb_heading-id-gsbp-5a9fb0b\" class=\"gspb_heading gspb_heading-id-gsbp-5a9fb0b \">3. Inverter firmware and SolisCloud settings<\/h3>\n\n<div class=\"wp-block-greenshift-blocks-infobox gspb_infoBox gspb_infoBox-id-gsbp-3624e98\" id=\"gspb_infoBox-id-gsbp-3624e98\"><div class=\"gs-box notice_type icon_type\"><div class=\"gs-box-icon\"><svg x=\"0px\" y=\"0px\" viewBox=\"0 0 486.463 486.463\"> <g> <g> <path d=\"M243.225,333.382c-13.6,0-25,11.4-25,25s11.4,25,25,25c13.1,0,25-11.4,24.4-24.4 C268.225,344.682,256.925,333.382,243.225,333.382z\"><\/path> <path d=\"M474.625,421.982c15.7-27.1,15.8-59.4,0.2-86.4l-156.6-271.2c-15.5-27.3-43.5-43.5-74.9-43.5s-59.4,16.3-74.9,43.4 l-156.8,271.5c-15.6,27.3-15.5,59.8,0.3,86.9c15.6,26.8,43.5,42.9,74.7,42.9h312.8 C430.725,465.582,458.825,449.282,474.625,421.982z M440.625,402.382c-8.7,15-24.1,23.9-41.3,23.9h-312.8 c-17,0-32.3-8.7-40.8-23.4c-8.6-14.9-8.7-32.7-0.1-47.7l156.8-271.4c8.5-14.9,23.7-23.7,40.9-23.7c17.1,0,32.4,8.9,40.9,23.8 l156.7,271.4C449.325,369.882,449.225,387.482,440.625,402.382z\"><\/path> <path d=\"M237.025,157.882c-11.9,3.4-19.3,14.2-19.3,27.3c0.6,7.9,1.1,15.9,1.7,23.8c1.7,30.1,3.4,59.6,5.1,89.7 c0.6,10.2,8.5,17.6,18.7,17.6c10.2,0,18.2-7.9,18.7-18.2c0-6.2,0-11.9,0.6-18.2c1.1-19.3,2.3-38.6,3.4-57.9 c0.6-12.5,1.7-25,2.3-37.5c0-4.5-0.6-8.5-2.3-12.5C260.825,160.782,248.925,155.082,237.025,157.882z\"><\/path> <\/g> <\/g> <\/svg><\/div><div class=\"gs-box-text\">\n<p class=\"wp-block-paragraph\"><strong>It is critical to update the inverter firmware after installation.<\/strong><br\/>All firware components must be updated: DSP firmware, HMI firmware, Major firmware and all other inverter firmware components.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>All SolisCloud control functions must be turned OFF.<\/strong><br\/>If any of the following functions are enabled in SolisCloud, it is not possible to control the inverter.<\/p>\n<\/div><\/div><\/div>\n\n<div id=\"gspb_text-id-gsbp-9d1a75c\" class=\"gspb_text gspb_text-id-gsbp-9d1a75c \"><strong>1)<\/strong> Solis AI, Peak Valley Arbitrage, Solis EMS and other automatic control functions must be turned OFF.<\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-e55cf01\" id=\"gspb_image-id-gsbp-e55cf01\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/7ee8933d-ff39-470a-9954-ed9a047db55c.png\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"440\" height=\"97\"><\/div>\n\n<div id=\"gspb_text-id-gsbp-bc4f3cf\" class=\"gspb_text gspb_text-id-gsbp-bc4f3cf \"><strong>2) <\/strong>Storage Mode \u2192 Charge &amp; Discharge time slots must be turned OFF.<\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-8c87b4a\" id=\"gspb_image-id-gsbp-8c87b4a\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/a717f2d7-a2a1-4512-9bb1-1f52a0b2bd01.png\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"448\" height=\"58\"><\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-135088d\" id=\"gspb_image-id-gsbp-135088d\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/92b0e6d1-1d08-4e21-ab19-fb5ce6638e08.png\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"478\" height=\"606\"><\/div>\n\n<div id=\"gspb_text-id-gsbp-6c01408\" class=\"gspb_text gspb_text-id-gsbp-6c01408 \"><strong>3)<\/strong> We recommend turning OFF Battery Saving, located under Battery Settings. This setting limits battery usage and reduces charging and discharging power. <\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-404f532\" id=\"gspb_image-id-gsbp-404f532\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/b9e223e8-9843-4d6c-ac6c-fbdd0d530d55.png\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"380\" height=\"53\"><\/div>\n\n<div id=\"gspb_text-id-gsbp-8fcea6c\" class=\"gspb_text gspb_text-id-gsbp-8fcea6c \"><strong>4)<\/strong> We recommend turning OFF Battery ECO Function, located under Settings -&gt; Function Settings. With some battery systems, it is not possible to charge the battery when it is empty and no PV production is available. <\/div>\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-4dad293\" id=\"gspb_image-id-gsbp-4dad293\"><img decoding=\"async\" src=\"https:\/\/docs.qilowatt.eu\/wp-content\/uploads\/2025\/09\/561ceaf2-fc25-418f-83c3-c583957126ee.png\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"350\" height=\"60\"><\/div>\n\n<h2 id=\"gspb_heading-id-gsbp-0addc18\" class=\"gspb_heading gspb_heading-id-gsbp-0addc18 \">Result<\/h2>\n\n<div id=\"gspb_text-id-gsbp-23ed942\" class=\"gspb_text gspb_text-id-gsbp-23ed942 \">Solis S6 inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables inverter control and energy optimization. <\/div>\n\n<h2 id=\"gspb_heading-id-gsbp-b394bfb\" class=\"gspb_heading gspb_heading-id-gsbp-b394bfb \">If it Doesn&#8217;t Work<\/h2>\n\n<div id=\"gspb_text-id-gsbp-66fe4d7\" class=\"gspb_text gspb_text-id-gsbp-66fe4d7 \">\u2022 If communication does not work, check the RS485 connections<br\/>\u2022 If the issue persists, contact our team: <a href=\"mailto:support@qilowatt.eu\">support@qilowatt.eu<\/a><\/div>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":7,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_gspb_post_css":"#gspb_heading-id-gsbp-04748af,#gspb_heading-id-gsbp-13b65a4,#gspb_heading-id-gsbp-c43af74{font-size:var(--wp--preset--font-size--medium)!important;margin-top:50px;margin-bottom:10px}#gspb_heading-id-gsbp-0566595,#gspb_heading-id-gsbp-75a5de1{font-size:18px;text-decoration:underline;margin-top:30px;margin-bottom:10px}#gspb_image-id-gsbp-b833ab6,#gspb_image-id-gsbp-cbc7b93,#gspb_infoBox-id-gsbp-3624e98 .gs-box{margin-top:10px;margin-bottom:10px}.gspb_text-id-gsbp-2fe239a,.gspb_text-id-gsbp-46e2044{margin-top:0!important}#gspb_image-id-gsbp-b833ab6 img,#gspb_image-id-gsbp-cbc7b93 img{vertical-align:top;display:inline-block;box-sizing:border-box;max-width:100%;height:auto}#gspb_heading-id-gsbp-5a9fb0b{font-size:18px;text-decoration:underline;margin-top:30px;margin-bottom:10px}.gs-box{padding:20px;border-left:5px solid transparent;margin-bottom:25px}.gs-box-text>p{margin-bottom:20px;margin-top:0}.gs-box-text>p:last-of-type{margin-bottom:0}.gs-box.notice_type{color:#856404;background-color:#fff3cd;border-color:#ffeeba}.gs-box.notice_type svg{fill:#f7a000}.gs-box.icon_type{display:flex}.gs-box.icon_type .gs-box-icon{width:28px;min-width:28px}.gs-box.icon_type .gs-box-text{flex-grow:1;margin:0 15px}#gspb_image-id-gsbp-8c87b4a img,#gspb_image-id-gsbp-e55cf01 img{vertical-align:top;display:inline-block;box-sizing:border-box;max-width:100%;height:auto}#gspb_image-id-gsbp-e55cf01{padding-top:10px;padding-bottom:10px}#gspb_image-id-gsbp-135088d,#gspb_image-id-gsbp-404f532,#gspb_image-id-gsbp-4dad293,#gspb_image-id-gsbp-8c87b4a{margin-top:0;padding-top:10px;padding-bottom:10px}#gspb_heading-id-gsbp-0addc18,#gspb_heading-id-gsbp-b394bfb{font-size:var(--wp--preset--font-size--medium)!important;margin-top:50px;margin-bottom:10px}#gspb_image-id-gsbp-135088d img,#gspb_image-id-gsbp-404f532 img,#gspb_image-id-gsbp-4dad293 img,#gspb_image-id-gsbp-fab5353 img{vertical-align:top;display:inline-block;box-sizing:border-box;max-width:100%;height:auto}#gspb_image-id-gsbp-fab5353{margin-top:10px;margin-bottom:10px}","footnotes":""},"doc_category":[190,145],"doc_tag":[],"class_list":["post-479","docs","type-docs","status-publish","hentry","doc_category-3-inverter-installation-pick-the-right-one","doc_category-inverter-installation"],"blocksy_meta":[],"year_month":"2026-07","word_count":351,"total_views":"0","reactions":{"happy":"1","normal":"0","sad":"0"},"author_info":{"name":"Qilowatt Support","author_nicename":"birgit-ertelqilowatt-eu","author_url":"https:\/\/docs.qilowatt.eu\/en\/author\/birgit-ertelqilowatt-eu\/"},"doc_category_info":[{"term_name":"3. Inverter Installation - pick the right one","term_url":"https:\/\/docs.qilowatt.eu\/en\/dcategory\/3-inverter-installation-pick-the-right-one\/"},{"term_name":"Inverter installation","term_url":"https:\/\/docs.qilowatt.eu\/en\/dcategory\/inverter-installation\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/docs\/479","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/comments?post=479"}],"version-history":[{"count":5,"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/docs\/479\/revisions"}],"predecessor-version":[{"id":927,"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/docs\/479\/revisions\/927"}],"wp:attachment":[{"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/media?parent=479"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/doc_category?post=479"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/docs.qilowatt.eu\/en\/wp-json\/wp\/v2\/doc_tag?post=479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}