<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>inverter &#8211; Qilowatt</title>
	<atom:link href="https://docs.qilowatt.eu/en/dtag/inverter/feed/" rel="self" type="application/rss+xml" />
	<link>https://docs.qilowatt.eu/en/</link>
	<description></description>
	<lastBuildDate>Thu, 30 Oct 2025 10:03:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://docs.qilowatt.eu/wp-content/uploads/2025/08/cropped-cropped-527027273_25002846699317774_491633004174988328_n-32x32.webp</url>
	<title>inverter &#8211; Qilowatt</title>
	<link>https://docs.qilowatt.eu/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GoodWe ET / ET Plus</title>
		<link>https://docs.qilowatt.eu/en/docs/goodwe-et-et-plus/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 10:58:25 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/goodwe-et-et-plus/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-ec3d15b" class="gspb_heading gspb_heading-id-gsbp-ec3d15b ">Introduction</h2>

<div id="gspb_text-id-gsbp-5a0d939" class="gspb_text gspb_text-id-gsbp-5a0d939 ">GoodWe ET and ET Plus hybrid inverters can be connected to the Qilowatt system via Modbus communication. This guide explains the necessary preparations, RS485 wiring, inverter settings, and operating modes. </div>

<h2 id="gspb_heading-id-gsbp-44f305d" class="gspb_heading gspb_heading-id-gsbp-44f305d ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-0660ba2" class="gspb_text gspb_text-id-gsbp-0660ba2 ">• Inverter and battery firmware are updated (latest version must be used)<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)<br/>• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/">Creating a user account</a></div>

<h2 id="gspb_heading-id-gsbp-f45fa70" class="gspb_heading gspb_heading-id-gsbp-f45fa70 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-01271fd" class="gspb_heading gspb_heading-id-gsbp-01271fd ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-14d703d" class="gspb_text gspb_text-id-gsbp-14d703d ">• Update the <strong>inverter and battery firmware</strong> before connecting.<br/>• Ensure the device has the <strong>latest firmware</strong>, since Qilowatt always relies on the newest Modbus protocol.</div>

<h3 id="gspb_heading-id-gsbp-8bc6974" class="gspb_heading gspb_heading-id-gsbp-8bc6974 ">2. RS485 connections</h3>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-90831a5" class="gspb_text gspb_text-id-gsbp-90831a5 "><strong>GoodWe ET 5–10 kW hybrid inverter (COM port):</strong><br/>• Pin 1 → RS485 A1<br/>• Pin 2 → RS485 B1<br/>Use Pin 1 (A) and Pin 2 (B) to connect the Qilowatt device.  <br/><br/>Note: Before installation, make sure the device has a <strong>Data port.</strong> </div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-c958d97" id="gspb_image-id-gsbp-c958d97"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-135241.png" data-src="" alt="" loading="lazy" width="505" height="221"></div>
</div>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-5e5c4d9" class="gspb_text gspb_text-id-gsbp-5e5c4d9 "><strong>GoodWe ET 15–30 kW hybrid inverter (EMS port):</strong><br/>• Pin 1 → RS485 A<br/>• Pin 2 → RS485 B<br/>• Pin 4 → GND<br/>• Pin 5 → CAN_L<br/>• Pin 6 → CAN_H<br/>Use Pin 1 (A) and Pin 2 (B) to connect the Qilowatt device.  </div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-7b2d1dd" id="gspb_image-id-gsbp-7b2d1dd"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-123533-1.png" data-src="" alt="" loading="lazy" width="177" height="121"></div>
</div>

<h3 id="gspb_heading-id-gsbp-97cb393" class="gspb_heading gspb_heading-id-gsbp-97cb393 ">3. Inverter settings</h3>

<div id="gspb_text-id-gsbp-c20f659" class="gspb_text gspb_text-id-gsbp-c20f659 ">• <strong>Modbus address:</strong> 247 (default)<br/>• <strong>Baud rate:</strong> 9600 (default)<br/><br/>If needed, the Modbus address can be changed via the <strong>GoodWe SEMS</strong> or <strong>Solar-Go</strong> apps.</div>

<h3 id="gspb_heading-id-gsbp-903e541" class="gspb_heading gspb_heading-id-gsbp-903e541 ">4. Operating modes</h3>

<div id="gspb_text-id-gsbp-13d2d41" class="gspb_text gspb_text-id-gsbp-13d2d41 ">• Set the inverter to <strong>Self-use</strong> mode (in older systems called <em>General</em>).<br/>• Disable all modes that prevent external control:<br/><strong>TOU</strong> (time-of-use)<br/><strong>ECO</strong><br/><strong>Peak Shaving</strong><br/>All remote controls</div>

<h3 id="gspb_heading-id-gsbp-9342a3d" class="gspb_heading gspb_heading-id-gsbp-9342a3d ">5. Why is a firmware update necessary?</h3>

<div id="gspb_text-id-gsbp-e8f962b" class="gspb_text gspb_text-id-gsbp-e8f962b ">Qilowatt always uses the manufacturer’s latest Modbus protocol. If the inverter or battery firmware is not updated, control may not work correctly. </div>

<h2 id="gspb_heading-id-gsbp-bfa484e" class="gspb_heading gspb_heading-id-gsbp-bfa484e ">Result</h2>

<div id="gspb_text-id-gsbp-6eff2c6" class="gspb_text gspb_text-id-gsbp-6eff2c6 ">The GoodWe ET / ET Plus inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables inverter control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-0e81270" class="gspb_heading gspb_heading-id-gsbp-0e81270 ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-620919e" class="gspb_text gspb_text-id-gsbp-620919e ">• If communication does not work, check the RS485 connections and confirm that the port is available.<br/>• If control does not function, make sure the inverter is in Self-use mode and that all other modes (TOU, ECO, Peak Shaving) are disabled.<br/>• If the Modbus address is incorrect, change it using the SEMS or Solar-Go app.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>. </div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Huawei SUN2000</title>
		<link>https://docs.qilowatt.eu/en/docs/huawei-sun2000/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 10:24:15 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/huawei-sun2000/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-720b811" class="gspb_heading gspb_heading-id-gsbp-720b811 ">Introduction</h2>

<div id="gspb_text-id-gsbp-00382c8" class="gspb_text gspb_text-id-gsbp-00382c8 ">Huawei SUN2000 inverters can be connected to the Qilowatt system via Modbus communication. This guide describes the required preparations, connections, and settings to ensure proper operation. </div>

<h2 id="gspb_heading-id-gsbp-deb9024" class="gspb_heading gspb_heading-id-gsbp-deb9024 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-004db6b" class="gspb_text gspb_text-id-gsbp-004db6b ">• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/">Creating a user account</a><br/>• Inverter, battery, and Smart Dongle firmware are updated<br/>• Smart Dongle removed (it interferes with Modbus communication)<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)</div>

<h2 id="gspb_heading-id-gsbp-0ca7007" class="gspb_heading gspb_heading-id-gsbp-0ca7007 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-5d22db7" class="gspb_heading gspb_heading-id-gsbp-5d22db7 ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-7c844ce" class="gspb_text gspb_text-id-gsbp-7c844ce ">• Update the firmware of the <strong>inverter, battery, and Smart Dongle</strong> before connecting.<br/>• Remove the <strong>Smart Dongle</strong>, as it interferes with Modbus communication and control will not work properly.</div>

<h3 id="gspb_heading-id-gsbp-0800f8b" class="gspb_heading gspb_heading-id-gsbp-0800f8b ">2. RS485 connections</h3>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-986838a" class="gspb_text gspb_text-id-gsbp-986838a ">Always refer to the installation manual of your specific model.<br/><br/><strong>Huawei SUN2000 M1 (10 kW) COM port:</strong><br/>• Pin 1 → RS485 A1<br/>• Pin 3 → RS485 B1<br/>• Pin 5 → GND (maandus)<br/>• Pin 7 → RS485 A2 (Smart Meter + battery)<br/>• Pin 9 → RS485 B2 (Smart Meter + battery)<br/>• Pin 13 → GND<br/><br/>For Qilowatt connection, use <strong>Pin 1 (A)</strong> and <strong>Pin 3 (B)</strong>.</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-f15cb81" id="gspb_image-id-gsbp-f15cb81"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-131806.png" data-src="" alt="" loading="lazy" width="333" height="324"></div>
</div>

<h3 id="gspb_heading-id-gsbp-08bb7b2" class="gspb_heading gspb_heading-id-gsbp-08bb7b2 ">3. Inverter settings</h3>

<div id="gspb_text-id-gsbp-437c8b6" class="gspb_text gspb_text-id-gsbp-437c8b6 ">• <strong>Modbus address:</strong> 1 (default)<br/>• <strong>Baud rate:</strong> 9600 (default)<br/><br/>If necessary, the Modbus address can be changed by Qilowatt support, but this is not required for standard connections.</div>

<h3 id="gspb_heading-id-gsbp-172aab8" class="gspb_heading gspb_heading-id-gsbp-172aab8 ">4. Operating modes</h3>

<div id="gspb_text-id-gsbp-58909a4" class="gspb_text gspb_text-id-gsbp-58909a4 ">• Set the inverter to <strong>Self-use</strong> mode.<br/>• In the FusionSolar app, disable all <strong>TOU (time-of-use) modes</strong> to avoid conflicts.</div>

<h3 id="gspb_heading-id-gsbp-5f4f97d" class="gspb_heading gspb_heading-id-gsbp-5f4f97d ">5. Why is a firmware update necessary?</h3>

<div id="gspb_text-id-gsbp-c0b9957" class="gspb_text gspb_text-id-gsbp-c0b9957 ">Qilowatt always uses the manufacturer’s latest Modbus protocol. If the inverter or battery firmware is not updated, control may not work correctly. </div>

<h2 id="gspb_heading-id-gsbp-77ad4c8" class="gspb_heading gspb_heading-id-gsbp-77ad4c8 ">Result</h2>

<div id="gspb_text-id-gsbp-442f5b0" class="gspb_text gspb_text-id-gsbp-442f5b0 ">The Huawei SUN2000 inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables inverter control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-ee891d3" class="gspb_heading gspb_heading-id-gsbp-ee891d3 ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-f2b0ca4" class="gspb_text gspb_text-id-gsbp-f2b0ca4 ">• If communication fails, check the RS485 connections (Pins 1 and 3 must be used correctly).<br/>• If the device does not respond to commands, ensure that the Smart Dongle has been removed.<br/>• If control does not work, verify the Modbus address and Baud rate values.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>.</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Solax X1/X3/Ultra</title>
		<link>https://docs.qilowatt.eu/en/docs/solax-x1-x3-ultra/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 09:44:55 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/solax-x1-x3-ultra/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-758b48e" class="gspb_heading gspb_heading-id-gsbp-758b48e ">Introduction</h2>

<div id="gspb_text-id-gsbp-07da56a" class="gspb_text gspb_text-id-gsbp-07da56a ">Solax inverters can be connected to the Qilowatt system via Modbus communication. This guide explains the required preparations, RS485 wiring, inverter settings, operating modes, and the importance of firmware updates. </div>

<h2 id="gspb_heading-id-gsbp-4865b94" class="gspb_heading gspb_heading-id-gsbp-4865b94 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-493aa01" class="gspb_text gspb_text-id-gsbp-493aa01 ">• Inverter and battery firmware are up to date<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)<br/>• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/" data-type="docs" data-id="22">Creating a user account</a></div>

<h2 id="gspb_heading-id-gsbp-a7c7743" class="gspb_heading gspb_heading-id-gsbp-a7c7743 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-bdf27d6" class="gspb_heading gspb_heading-id-gsbp-bdf27d6 ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-d61de94" class="gspb_text gspb_text-id-gsbp-d61de94 ">• Update the inverter and battery firmware before connecting.<br/>• Ensure you are using the latest manufacturer version, since Qilowatt always relies on the newest Modbus protocol.</div>

<h3 id="gspb_heading-id-gsbp-6f0a683" class="gspb_heading gspb_heading-id-gsbp-6f0a683 ">2. RS485 connections</h3>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-37de279" class="gspb_text gspb_text-id-gsbp-37de279 "><strong>Solax X1/X3 inverter COM port:</strong><br/>• Pin 4 → RS485 A<br/>• Pin 5 → RS485 B<br/>Use Pin 4 (A) and Pin 5 (B) to connect the Qilowatt device.   </div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-b190f33" id="gspb_image-id-gsbp-b190f33"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-123533.png" data-src="" alt="" loading="lazy" width="177" height="121"></div>
</div>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-f8962a8" class="gspb_text gspb_text-id-gsbp-f8962a8 "><strong>Solax Ultra inverter RS485 port:</strong><br/>• Pin 1 → RS485 A<br/>• Pin 2 → RS485 B<br/>Pin numbers may vary by model – always check the specific device manual.</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-90feba4" id="gspb_image-id-gsbp-90feba4"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-123533.png" data-src="" alt="" loading="lazy" width="177" height="121"></div>
</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-4756e47" id="gspb_image-id-gsbp-4756e47"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-03-112721.png" data-src="" alt="" loading="lazy" width="391" height="568"></div>

<h3 id="gspb_heading-id-gsbp-3765bc2" class="gspb_heading gspb_heading-id-gsbp-3765bc2 ">3. Inverter settings</h3>

<div id="gspb_text-id-gsbp-b8ac974" class="gspb_text gspb_text-id-gsbp-b8ac974 ">• <strong>Unlock password:</strong> 2014<br/>Solax is the only manufacturer that requires an Unlock Password for Modbus control. If the password is changed, Qilowatt will no longer be able to control the inverter.<br/>• <strong>Modbus address:</strong> 1 (default)<br/>• <strong>Baud rate:</strong> 9600<br/>The inverter default Baud rate is 19200. For communication with Qilowatt, this must be changed to <strong>9600</strong>. If needed, the Qilowatt support team can adjust this in the Qilowatt device as well.   <br/><br/>Modbus address and Baud rate settings can also be modified via the <strong>Solax SolarCloud app.</strong></div>

<h3 id="gspb_heading-id-gsbp-e13bd11" class="gspb_heading gspb_heading-id-gsbp-e13bd11 ">4. Operating modes</h3>

<div id="gspb_text-id-gsbp-b08e465" class="gspb_text gspb_text-id-gsbp-b08e465 ">• <strong>Mandatory step</strong>: enable battery usage<br/>Discharge period: 00:00–23:59<br/>Charge period: 00:00–00:00<br/><strong>• Installer password:</strong> 2014<br/>Test whether you can access Remote control in Solax Cloud with this password.<br/>• Disable all remote controls, AI features, and time-of-use schedules to avoid conflicts.<br/>• Operation takes place in <strong>Back-Up mode</strong>.<br/>! In Self-use mode, the inverter will not accept commands if the battery is empty.<br/>• <strong>The Solax Datahub</strong> must be removed – even if not actively controlling, it interferes with communication. </div>

<h3 id="gspb_heading-id-gsbp-a20ca5e" class="gspb_heading gspb_heading-id-gsbp-a20ca5e ">5. Why is a firmware update necessary?</h3>

<div id="gspb_text-id-gsbp-0f1c012" class="gspb_text gspb_text-id-gsbp-0f1c012 ">Qilowatt always uses the manufacturer’s latest Modbus protocol. If the inverter or battery firmware is not updated, control may not work correctly. </div>

<h2 id="gspb_heading-id-gsbp-bc5f58c" class="gspb_heading gspb_heading-id-gsbp-bc5f58c ">Result</h2>

<div id="gspb_text-id-gsbp-f06072f" class="gspb_text gspb_text-id-gsbp-f06072f ">The Solax inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables device control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-8f86f7c" class="gspb_heading gspb_heading-id-gsbp-8f86f7c ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-93ad77b" class="gspb_text gspb_text-id-gsbp-93ad77b ">• If RS485 communication does not work, check that you used the correct pins according to the model.<br/>• If communication still fails, verify the Modbus address and Baud rate values.<br/>• If control is not functioning, make sure the Unlock Password is still set to 2014.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>.</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fronius</title>
		<link>https://docs.qilowatt.eu/en/docs/fronius/</link>
		
		<dc:creator><![CDATA[marko]]></dc:creator>
		<pubDate>Thu, 28 Aug 2025 17:38:03 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/fronius/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-90af34a" class="gspb_heading gspb_heading-id-gsbp-90af34a ">Introduction</h2>

<div id="gspb_text-id-gsbp-254a877" class="gspb_text gspb_text-id-gsbp-254a877 ">Fronius inverters can be connected to the Qilowatt system using a Modbus module. This guide explains the necessary settings, module installation, and startup steps. </div>

<h2 id="gspb_heading-id-gsbp-defdfb2" class="gspb_heading gspb_heading-id-gsbp-defdfb2 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-48dc402" class="gspb_text gspb_text-id-gsbp-48dc402 ">• The inverter is operational and configured according to the manufacturer’s instructions<br/>• A Modbus R1 or R2 module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)<br/>• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/" data-type="docs" data-id="22">Creating a user account</a></div>

<h2 id="gspb_heading-id-gsbp-63d658a" class="gspb_heading gspb_heading-id-gsbp-63d658a ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-c9b37fe" class="gspb_heading gspb_heading-id-gsbp-c9b37fe ">Configuring the inverter in the Fronius web interface</h3>

<div id="gspb_text-id-gsbp-3cb77b0" class="gspb_text gspb_text-id-gsbp-3cb77b0 "><strong>1.</strong> Open the <strong>Fronius web interface</strong> and go to the <strong>Modbus Data Export </strong>view.<br/><strong>2. </strong>Configure the following settings:<br/>• <strong>Modbus RTU Interface 1:</strong> slave<br/><strong>• Baud Rate:</strong> 9600<br/><strong>• Parity:</strong> none<br/><strong>• SunSpec Model Type:</strong> int + PF<br/><strong>• Inverter Address:</strong> 3<br/><strong>• Inverter Control via Modbus:</strong> On</div>

<h3 id="gspb_heading-id-gsbp-f93e3b8" class="gspb_heading gspb_heading-id-gsbp-f93e3b8 ">Installing the module</h3>

<div id="gspb_text-id-gsbp-ff5182d" class="gspb_text gspb_text-id-gsbp-ff5182d "><strong>1.</strong> Install the <strong>MODBUS R1 / R2 module</strong> according to the installation manual.<br/><strong>2. </strong>Connect the communication cable (CAT5 or CAT6) between the module’s RS485 port and the inverter’s Modbus port:<br/>• <strong>M1+ → A</strong><br/>• <strong>M1- → B</strong></div>

<h3 id="gspb_heading-id-gsbp-3cd9be9" class="gspb_heading gspb_heading-id-gsbp-3cd9be9 ">Starting the module</h3>

<div id="gspb_text-id-gsbp-6451caa" class="gspb_text gspb_text-id-gsbp-6451caa "><strong>1.</strong> Switch on the circuit breaker of the MODBUS R1 / R2 module (or insert the fuse).<br/><strong>2. </strong>Check if the module’s <strong>white LED indicator</strong> starts flashing rapidly.<br/><strong>3.</strong> Connect the module to your home WiFi network → <a href="https://docs.qilowatt.eu/en/docs/connecting-the-device-to-wifi/" data-type="docs" data-id="23">Connecting the device to WiFi.</a><br/><strong>•</strong> Place the module where the WiFi signal is strong.<br/>• Use a WiFi range extender if necessary.</div>

<h2 id="gspb_heading-id-gsbp-281c81f" class="gspb_heading gspb_heading-id-gsbp-281c81f ">Result</h2>

<div id="gspb_text-id-gsbp-19e66e2" class="gspb_text gspb_text-id-gsbp-19e66e2 ">The Fronius inverter is successfully connected to the Qilowatt system. The Modbus module transmits data and enables device control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-5c03b9b" class="gspb_heading gspb_heading-id-gsbp-5c03b9b ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-d617243" class="gspb_text gspb_text-id-gsbp-d617243 ">• If the LED indicator does not light up, check the connections and circuit protection.<br/>• If communication does not work, verify that the Modbus settings in the web interface are correct.<br/>• If the module does not connect to WiFi, follow the guide → <a href="https://docs.qilowatt.eu/en/docs/resetting-wifi-settings/" data-type="docs" data-id="52">Resetting WiFi settings</a>.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>. </div>

<p></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Deye / Sunsynk / Sol-Ark</title>
		<link>https://docs.qilowatt.eu/en/docs/deye-sunsynk-sol-ark/</link>
		
		<dc:creator><![CDATA[marko]]></dc:creator>
		<pubDate>Thu, 28 Aug 2025 17:37:08 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/deye-sunsynk-sol-ark/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-54d638e" class="gspb_heading gspb_heading-id-gsbp-54d638e ">Introduction</h2>

<div id="gspb_text-id-gsbp-26d610d" class="gspb_text gspb_text-id-gsbp-26d610d ">Deye, Sunsynk and Sol-Ark inverters can be connected to the Qilowatt system using a Modbus module. This guide explains the necessary settings, wiring connections, and how to start the module. </div>

<h2 id="gspb_heading-id-gsbp-b1f36d1" class="gspb_heading gspb_heading-id-gsbp-b1f36d1 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-9e5501d" class="gspb_text gspb_text-id-gsbp-9e5501d ">• A technician has verified that the inverter is operating correctly<br/>• The inverter is able to charge batteries from the grid and, if permitted, sell energy back to the grid<br/>• Battery maximum power limits are taken into account<br/>• A Modbus R1 or R2 module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)</div>

<h2 id="gspb_heading-id-gsbp-43464ca" class="gspb_heading gspb_heading-id-gsbp-43464ca ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-9106fc8" class="gspb_heading gspb_heading-id-gsbp-9106fc8 ">Inverter settings</h3>

<div id="gspb_text-id-gsbp-9a54607" class="gspb_text gspb_text-id-gsbp-9a54607 "><strong>1. </strong>Open Deye inverter menu.<br/><strong>2.</strong> Configure the following settings:<br/>• <strong>Modbus SN (address):</strong> 01<br/>• <strong>Master/Slave:</strong> Slave<br/><strong>• Modbus baudrate:</strong> 9600<br/><strong>• Time of Use:</strong> activated</div>

<h3 id="gspb_heading-id-gsbp-19e1e31" class="gspb_heading gspb_heading-id-gsbp-19e1e31 ">Installing the module</h3>

<div id="gspb_text-id-gsbp-0606274" class="gspb_text gspb_text-id-gsbp-0606274 "><strong>1.</strong> Install the <strong>MODBUS module</strong> according to the installation manual.<br/><strong>2.</strong> Connect the communication cable (CAT5 or CAT6) from the module’s RS485 A and B terminals to the corresponding inverter port.<br/><br/>⚠️ <strong>Important!</strong><br/><strong>• </strong>If the inverter mainboard has a <strong>DRM port</strong>:<br/>Connect the MODBUS R2 module terminals A and B to the inverter <strong>BMS port</strong> pins:<br/><strong>• </strong>Pin 1 → B+<br/><strong>• </strong>Pin 2 → A-<br/>If the BMS port is already in use by the battery, use the<strong> Y-splitter </strong>included in the installation kit.<br/><br/><strong>• </strong>If the inverter <strong>does not have a DRM</strong> port:<br/>Connect the MODBUS R2 module terminals A and B to the inverter <strong>Modbus port</strong> pins:<br/><strong>• </strong>Pin 7 → A-<br/><strong>• </strong>Pin 8 → B+</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-06837e0" id="gspb_image-id-gsbp-06837e0"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/08/528224762_1124649282925785_6576931699721567072_n.webp" data-src="" alt="" loading="lazy" width="768" height="654"></div>

<h3 id="gspb_heading-id-gsbp-ead0a41" class="gspb_heading gspb_heading-id-gsbp-ead0a41 ">Starting the module</h3>

<div id="gspb_text-id-gsbp-832a9ec" class="gspb_text gspb_text-id-gsbp-832a9ec "><strong>1. </strong>Switch on the circuit breaker of the MODBUS R1 / R2 module (or insert the fuse).<br/><strong>2.</strong> Check if the module’s <strong>white LED indicator</strong> starts flashing rapidly.<br/><strong>3.</strong> Connect the module to your home WiFi network → <a href="https://docs.qilowatt.eu/en/docs/connecting-the-device-to-wifi/" data-type="docs" data-id="23">Connecting the device to WiFi.</a><br/><strong>4.</strong> Place the module in a location with a strong WiFi signal.<br/><strong>5. </strong>If needed, use a WiFi range extender.</div>

<h2 id="gspb_heading-id-gsbp-fed8eac" class="gspb_heading gspb_heading-id-gsbp-fed8eac ">Result</h2>

<div id="gspb_text-id-gsbp-c5c9df2" class="gspb_text gspb_text-id-gsbp-c5c9df2 ">The inverter is successfully connected to the Qilowatt system. The Modbus module transmits data and enables device control and optimization. </div>

<h2 id="gspb_heading-id-gsbp-a223463" class="gspb_heading gspb_heading-id-gsbp-a223463 ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-7b427dd" class="gspb_text gspb_text-id-gsbp-7b427dd ">• If the LED indicator does not light up, check the connections and circuit protection.<br/>• If communication does not work, verify that the Modbus address and baudrate are set correctly.<br/>• If the module does not connect to WiFi, follow the guide → <a href="https://docs.qilowatt.eu/en/docs/resetting-wifi-settings/" data-type="docs" data-id="52">Resetting WiFi settings</a><br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>. </div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
