<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>huawei &#8211; Qilowatt</title>
	<atom:link href="https://docs.qilowatt.eu/en/dtag/huawei/feed/" rel="self" type="application/rss+xml" />
	<link>https://docs.qilowatt.eu/en/</link>
	<description></description>
	<lastBuildDate>Thu, 30 Oct 2025 10:03:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://docs.qilowatt.eu/wp-content/uploads/2025/08/cropped-cropped-527027273_25002846699317774_491633004174988328_n-32x32.webp</url>
	<title>huawei &#8211; Qilowatt</title>
	<link>https://docs.qilowatt.eu/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Huawei SUN2000</title>
		<link>https://docs.qilowatt.eu/en/docs/huawei-sun2000/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 10:24:15 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/huawei-sun2000/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-720b811" class="gspb_heading gspb_heading-id-gsbp-720b811 ">Introduction</h2>

<div id="gspb_text-id-gsbp-00382c8" class="gspb_text gspb_text-id-gsbp-00382c8 ">Huawei SUN2000 inverters can be connected to the Qilowatt system via Modbus communication. This guide describes the required preparations, connections, and settings to ensure proper operation. </div>

<h2 id="gspb_heading-id-gsbp-deb9024" class="gspb_heading gspb_heading-id-gsbp-deb9024 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-004db6b" class="gspb_text gspb_text-id-gsbp-004db6b ">• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/">Creating a user account</a><br/>• Inverter, battery, and Smart Dongle firmware are updated<br/>• Smart Dongle removed (it interferes with Modbus communication)<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)</div>

<h2 id="gspb_heading-id-gsbp-0ca7007" class="gspb_heading gspb_heading-id-gsbp-0ca7007 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-5d22db7" class="gspb_heading gspb_heading-id-gsbp-5d22db7 ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-7c844ce" class="gspb_text gspb_text-id-gsbp-7c844ce ">• Update the firmware of the <strong>inverter, battery, and Smart Dongle</strong> before connecting.<br/>• Remove the <strong>Smart Dongle</strong>, as it interferes with Modbus communication and control will not work properly.</div>

<h3 id="gspb_heading-id-gsbp-0800f8b" class="gspb_heading gspb_heading-id-gsbp-0800f8b ">2. RS485 connections</h3>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-986838a" class="gspb_text gspb_text-id-gsbp-986838a ">Always refer to the installation manual of your specific model.<br/><br/><strong>Huawei SUN2000 M1 (10 kW) COM port:</strong><br/>• Pin 1 → RS485 A1<br/>• Pin 3 → RS485 B1<br/>• Pin 5 → GND (maandus)<br/>• Pin 7 → RS485 A2 (Smart Meter + battery)<br/>• Pin 9 → RS485 B2 (Smart Meter + battery)<br/>• Pin 13 → GND<br/><br/>For Qilowatt connection, use <strong>Pin 1 (A)</strong> and <strong>Pin 3 (B)</strong>.</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-f15cb81" id="gspb_image-id-gsbp-f15cb81"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-131806.png" data-src="" alt="" loading="lazy" width="333" height="324"></div>
</div>

<h3 id="gspb_heading-id-gsbp-08bb7b2" class="gspb_heading gspb_heading-id-gsbp-08bb7b2 ">3. Inverter settings</h3>

<div id="gspb_text-id-gsbp-437c8b6" class="gspb_text gspb_text-id-gsbp-437c8b6 ">• <strong>Modbus address:</strong> 1 (default)<br/>• <strong>Baud rate:</strong> 9600 (default)<br/><br/>If necessary, the Modbus address can be changed by Qilowatt support, but this is not required for standard connections.</div>

<h3 id="gspb_heading-id-gsbp-172aab8" class="gspb_heading gspb_heading-id-gsbp-172aab8 ">4. Operating modes</h3>

<div id="gspb_text-id-gsbp-58909a4" class="gspb_text gspb_text-id-gsbp-58909a4 ">• Set the inverter to <strong>Self-use</strong> mode.<br/>• In the FusionSolar app, disable all <strong>TOU (time-of-use) modes</strong> to avoid conflicts.</div>

<h3 id="gspb_heading-id-gsbp-5f4f97d" class="gspb_heading gspb_heading-id-gsbp-5f4f97d ">5. Why is a firmware update necessary?</h3>

<div id="gspb_text-id-gsbp-c0b9957" class="gspb_text gspb_text-id-gsbp-c0b9957 ">Qilowatt always uses the manufacturer’s latest Modbus protocol. If the inverter or battery firmware is not updated, control may not work correctly. </div>

<h2 id="gspb_heading-id-gsbp-77ad4c8" class="gspb_heading gspb_heading-id-gsbp-77ad4c8 ">Result</h2>

<div id="gspb_text-id-gsbp-442f5b0" class="gspb_text gspb_text-id-gsbp-442f5b0 ">The Huawei SUN2000 inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables inverter control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-ee891d3" class="gspb_heading gspb_heading-id-gsbp-ee891d3 ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-f2b0ca4" class="gspb_text gspb_text-id-gsbp-f2b0ca4 ">• If communication fails, check the RS485 connections (Pins 1 and 3 must be used correctly).<br/>• If the device does not respond to commands, ensure that the Smart Dongle has been removed.<br/>• If control does not work, verify the Modbus address and Baud rate values.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>.</div>