<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>3. Inverter Installation &#8211; pick the right one &#8211; Qilowatt</title>
	<atom:link href="https://docs.qilowatt.eu/en/dcategory/3-inverter-installation-pick-the-right-one/feed/" rel="self" type="application/rss+xml" />
	<link>https://docs.qilowatt.eu/en/</link>
	<description></description>
	<lastBuildDate>Mon, 20 Apr 2026 11:00:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://docs.qilowatt.eu/wp-content/uploads/2025/08/cropped-cropped-527027273_25002846699317774_491633004174988328_n-32x32.webp</url>
	<title>3. Inverter Installation &#8211; pick the right one &#8211; Qilowatt</title>
	<link>https://docs.qilowatt.eu/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Deye / Sunsynk / Sol-Ark</title>
		<link>https://docs.qilowatt.eu/en/docs/deye-sunsynk-sol-ark/</link>
		
		<dc:creator><![CDATA[marko]]></dc:creator>
		<pubDate>Thu, 28 Aug 2025 17:37:08 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/deye-sunsynk-sol-ark/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-54d638e" class="gspb_heading gspb_heading-id-gsbp-54d638e ">Introduction</h2>

<div id="gspb_text-id-gsbp-26d610d" class="gspb_text gspb_text-id-gsbp-26d610d ">Deye, Sunsynk and Sol-Ark inverters can be connected to the Qilowatt system using a Modbus module. This guide explains the necessary settings, wiring connections, and how to start the module. </div>

<h2 id="gspb_heading-id-gsbp-b1f36d1" class="gspb_heading gspb_heading-id-gsbp-b1f36d1 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-9e5501d" class="gspb_text gspb_text-id-gsbp-9e5501d ">• A technician has verified that the inverter is operating correctly<br/>• The inverter is able to charge batteries from the grid and, if permitted, sell energy back to the grid<br/>• Battery maximum power limits are taken into account<br/>• A Modbus R1 or R2 module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)</div>

<h2 id="gspb_heading-id-gsbp-43464ca" class="gspb_heading gspb_heading-id-gsbp-43464ca ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-9106fc8" class="gspb_heading gspb_heading-id-gsbp-9106fc8 ">Inverter settings</h3>

<div id="gspb_text-id-gsbp-9a54607" class="gspb_text gspb_text-id-gsbp-9a54607 "><strong>1. </strong>Open Deye inverter menu.<br/><strong>2.</strong> Configure the following settings:<br/>• <strong>Modbus SN (address):</strong> 01<br/>• <strong>Master/Slave:</strong> Slave<br/><strong>• Modbus baudrate:</strong> 9600<br/><strong>• Time of Use:</strong> activated</div>

<h3 id="gspb_heading-id-gsbp-19e1e31" class="gspb_heading gspb_heading-id-gsbp-19e1e31 ">Installing the module</h3>

<div id="gspb_text-id-gsbp-0606274" class="gspb_text gspb_text-id-gsbp-0606274 "><strong>1.</strong> Install the <strong>MODBUS module</strong> according to the installation manual.<br/><strong>2.</strong> Connect the communication cable (CAT5 or CAT6) from the module’s RS485 A and B terminals to the corresponding inverter port.<br/><br/>⚠️ <strong>Important!</strong><br/><strong>• </strong>If the inverter mainboard has a <strong>DRM port</strong>:<br/>Connect the MODBUS R2 module terminals A and B to the inverter <strong>BMS port</strong> pins:<br/><strong>• </strong>Pin 1 → B+<br/><strong>• </strong>Pin 2 → A-<br/>If the BMS port is already in use by the battery, use the<strong> Y-splitter </strong>included in the installation kit.<br/><br/><strong>• </strong>If the inverter <strong>does not have a DRM</strong> port:<br/>Connect the MODBUS R2 module terminals A and B to the inverter <strong>Modbus port</strong> pins:<br/><strong>• </strong>Pin 7 → A-<br/><strong>• </strong>Pin 8 → B+</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-06837e0" id="gspb_image-id-gsbp-06837e0"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/08/528224762_1124649282925785_6576931699721567072_n.webp" data-src="" alt="" loading="lazy" width="768" height="654"></div>

<h3 id="gspb_heading-id-gsbp-ead0a41" class="gspb_heading gspb_heading-id-gsbp-ead0a41 ">Starting the module</h3>

<div id="gspb_text-id-gsbp-832a9ec" class="gspb_text gspb_text-id-gsbp-832a9ec "><strong>1. </strong>Switch on the circuit breaker of the MODBUS R1 / R2 module (or insert the fuse).<br/><strong>2.</strong> Check if the module’s <strong>white LED indicator</strong> starts flashing rapidly.<br/><strong>3.</strong> Connect the module to your home WiFi network → <a href="https://docs.qilowatt.eu/en/docs/connecting-the-device-to-wifi/" data-type="docs" data-id="23">Connecting the device to WiFi.</a><br/><strong>4.</strong> Place the module in a location with a strong WiFi signal.<br/><strong>5. </strong>If needed, use a WiFi range extender.</div>

<h2 id="gspb_heading-id-gsbp-fed8eac" class="gspb_heading gspb_heading-id-gsbp-fed8eac ">Result</h2>

<div id="gspb_text-id-gsbp-c5c9df2" class="gspb_text gspb_text-id-gsbp-c5c9df2 ">The inverter is successfully connected to the Qilowatt system. The Modbus module transmits data and enables device control and optimization. </div>

<h2 id="gspb_heading-id-gsbp-a223463" class="gspb_heading gspb_heading-id-gsbp-a223463 ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-7b427dd" class="gspb_text gspb_text-id-gsbp-7b427dd ">• If the LED indicator does not light up, check the connections and circuit protection.<br/>• If communication does not work, verify that the Modbus address and baudrate are set correctly.<br/>• If the module does not connect to WiFi, follow the guide → <a href="https://docs.qilowatt.eu/en/docs/resetting-wifi-settings/" data-type="docs" data-id="52">Resetting WiFi settings</a><br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>. </div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fronius</title>
		<link>https://docs.qilowatt.eu/en/docs/fronius/</link>
		
		<dc:creator><![CDATA[marko]]></dc:creator>
		<pubDate>Thu, 28 Aug 2025 17:38:03 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/fronius/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-90af34a" class="gspb_heading gspb_heading-id-gsbp-90af34a ">Introduction</h2>

<div id="gspb_text-id-gsbp-254a877" class="gspb_text gspb_text-id-gsbp-254a877 ">Fronius inverters can be connected to the Qilowatt system using a Modbus module. This guide explains the necessary settings, module installation, and startup steps. </div>

<h2 id="gspb_heading-id-gsbp-defdfb2" class="gspb_heading gspb_heading-id-gsbp-defdfb2 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-48dc402" class="gspb_text gspb_text-id-gsbp-48dc402 ">• The inverter is operational and configured according to the manufacturer’s instructions<br/>• A Modbus R1 or R2 module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)<br/>• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/" data-type="docs" data-id="22">Creating a user account</a></div>

<h2 id="gspb_heading-id-gsbp-63d658a" class="gspb_heading gspb_heading-id-gsbp-63d658a ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-c9b37fe" class="gspb_heading gspb_heading-id-gsbp-c9b37fe ">Configuring the inverter in the Fronius web interface</h3>

<div id="gspb_text-id-gsbp-3cb77b0" class="gspb_text gspb_text-id-gsbp-3cb77b0 "><strong>1.</strong> Open the <strong>Fronius web interface</strong> and go to the <strong>Modbus Data Export </strong>view.<br/><strong>2. </strong>Configure the following settings:<br/>• <strong>Modbus RTU Interface 1:</strong> slave<br/><strong>• Baud Rate:</strong> 9600<br/><strong>• Parity:</strong> none<br/><strong>• SunSpec Model Type:</strong> int + PF<br/><strong>• Inverter Address:</strong> 3<br/><strong>• Inverter Control via Modbus:</strong> On</div>

<h3 id="gspb_heading-id-gsbp-f93e3b8" class="gspb_heading gspb_heading-id-gsbp-f93e3b8 ">Installing the module</h3>

<div id="gspb_text-id-gsbp-ff5182d" class="gspb_text gspb_text-id-gsbp-ff5182d "><strong>1.</strong> Install the <strong>MODBUS R1 / R2 module</strong> according to the installation manual.<br/><strong>2. </strong>Connect the communication cable (CAT5 or CAT6) between the module’s RS485 port and the inverter’s Modbus port:<br/>• <strong>M1+ → A</strong><br/>• <strong>M1- → B</strong></div>

<h3 id="gspb_heading-id-gsbp-3cd9be9" class="gspb_heading gspb_heading-id-gsbp-3cd9be9 ">Starting the module</h3>

<div id="gspb_text-id-gsbp-6451caa" class="gspb_text gspb_text-id-gsbp-6451caa "><strong>1.</strong> Switch on the circuit breaker of the MODBUS R1 / R2 module (or insert the fuse).<br/><strong>2. </strong>Check if the module’s <strong>white LED indicator</strong> starts flashing rapidly.<br/><strong>3.</strong> Connect the module to your home WiFi network → <a href="https://docs.qilowatt.eu/en/docs/connecting-the-device-to-wifi/" data-type="docs" data-id="23">Connecting the device to WiFi.</a><br/><strong>•</strong> Place the module where the WiFi signal is strong.<br/>• Use a WiFi range extender if necessary.</div>

<h2 id="gspb_heading-id-gsbp-281c81f" class="gspb_heading gspb_heading-id-gsbp-281c81f ">Result</h2>

<div id="gspb_text-id-gsbp-19e66e2" class="gspb_text gspb_text-id-gsbp-19e66e2 ">The Fronius inverter is successfully connected to the Qilowatt system. The Modbus module transmits data and enables device control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-5c03b9b" class="gspb_heading gspb_heading-id-gsbp-5c03b9b ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-d617243" class="gspb_text gspb_text-id-gsbp-d617243 ">• If the LED indicator does not light up, check the connections and circuit protection.<br/>• If communication does not work, verify that the Modbus settings in the web interface are correct.<br/>• If the module does not connect to WiFi, follow the guide → <a href="https://docs.qilowatt.eu/en/docs/resetting-wifi-settings/" data-type="docs" data-id="52">Resetting WiFi settings</a>.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>. </div>

<p></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Solax X1/X3/Ultra</title>
		<link>https://docs.qilowatt.eu/en/docs/solax-x1-x3-ultra/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 09:44:55 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/solax-x1-x3-ultra/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-758b48e" class="gspb_heading gspb_heading-id-gsbp-758b48e ">Introduction</h2>

<div id="gspb_text-id-gsbp-07da56a" class="gspb_text gspb_text-id-gsbp-07da56a ">Solax inverters can be connected to the Qilowatt system via Modbus communication. This guide explains the required preparations, RS485 wiring, inverter settings, operating modes, and the importance of firmware updates. </div>

<h2 id="gspb_heading-id-gsbp-4865b94" class="gspb_heading gspb_heading-id-gsbp-4865b94 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-493aa01" class="gspb_text gspb_text-id-gsbp-493aa01 ">• Inverter and battery firmware are up to date<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)<br/>• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/" data-type="docs" data-id="22">Creating a user account</a></div>

<h2 id="gspb_heading-id-gsbp-a7c7743" class="gspb_heading gspb_heading-id-gsbp-a7c7743 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-bdf27d6" class="gspb_heading gspb_heading-id-gsbp-bdf27d6 ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-d61de94" class="gspb_text gspb_text-id-gsbp-d61de94 ">• Update the inverter and battery firmware before connecting.<br/>• Ensure you are using the latest manufacturer version, since Qilowatt always relies on the newest Modbus protocol.</div>

<h3 id="gspb_heading-id-gsbp-6f0a683" class="gspb_heading gspb_heading-id-gsbp-6f0a683 ">2. RS485 connections</h3>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-37de279" class="gspb_text gspb_text-id-gsbp-37de279 "><strong>Solax X1/X3 inverter COM port:</strong><br/>• Pin 4 → RS485 A<br/>• Pin 5 → RS485 B<br/>Use Pin 4 (A) and Pin 5 (B) to connect the Qilowatt device.   </div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-b190f33" id="gspb_image-id-gsbp-b190f33"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-123533.png" data-src="" alt="" loading="lazy" width="177" height="121"></div>
</div>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-f8962a8" class="gspb_text gspb_text-id-gsbp-f8962a8 "><strong>Solax Ultra inverter RS485 port:</strong><br/>• Pin 1 → RS485 A<br/>• Pin 2 → RS485 B<br/>Pin numbers may vary by model – always check the specific device manual.</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-90feba4" id="gspb_image-id-gsbp-90feba4"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-123533.png" data-src="" alt="" loading="lazy" width="177" height="121"></div>
</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-4756e47" id="gspb_image-id-gsbp-4756e47"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-03-112721.png" data-src="" alt="" loading="lazy" width="391" height="568"></div>

<h3 id="gspb_heading-id-gsbp-3765bc2" class="gspb_heading gspb_heading-id-gsbp-3765bc2 ">3. Inverter settings</h3>

<div id="gspb_text-id-gsbp-b8ac974" class="gspb_text gspb_text-id-gsbp-b8ac974 ">• <strong>Unlock password:</strong> 2014<br/>Solax is the only manufacturer that requires an Unlock Password for Modbus control. If the password is changed, Qilowatt will no longer be able to control the inverter.<br/>• <strong>Modbus address:</strong> 1 (default)<br/>• <strong>Baud rate:</strong> 9600<br/>The inverter default Baud rate is 19200. For communication with Qilowatt, this must be changed to <strong>9600</strong>. If needed, the Qilowatt support team can adjust this in the Qilowatt device as well.   <br/><br/>Modbus address and Baud rate settings can also be modified via the <strong>Solax SolarCloud app.</strong></div>

<h3 id="gspb_heading-id-gsbp-e13bd11" class="gspb_heading gspb_heading-id-gsbp-e13bd11 ">4. Operating modes</h3>

<div id="gspb_text-id-gsbp-b08e465" class="gspb_text gspb_text-id-gsbp-b08e465 ">• <strong>Mandatory step</strong>: enable battery usage<br/>Discharge period: 00:00–23:59<br/>Charge period: 00:00–00:00<br/><strong>• Installer password:</strong> 2014<br/>Test whether you can access Remote control in Solax Cloud with this password.<br/>• Disable all remote controls, AI features, and time-of-use schedules to avoid conflicts.<br/>• Operation takes place in <strong>Back-Up mode</strong>.<br/>! In Self-use mode, the inverter will not accept commands if the battery is empty.<br/>• <strong>The Solax Datahub</strong> must be removed – even if not actively controlling, it interferes with communication. </div>

<h3 id="gspb_heading-id-gsbp-a20ca5e" class="gspb_heading gspb_heading-id-gsbp-a20ca5e ">5. Why is a firmware update necessary?</h3>

<div id="gspb_text-id-gsbp-0f1c012" class="gspb_text gspb_text-id-gsbp-0f1c012 ">Qilowatt always uses the manufacturer’s latest Modbus protocol. If the inverter or battery firmware is not updated, control may not work correctly. </div>

<h2 id="gspb_heading-id-gsbp-bc5f58c" class="gspb_heading gspb_heading-id-gsbp-bc5f58c ">Result</h2>

<div id="gspb_text-id-gsbp-f06072f" class="gspb_text gspb_text-id-gsbp-f06072f ">The Solax inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables device control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-8f86f7c" class="gspb_heading gspb_heading-id-gsbp-8f86f7c ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-93ad77b" class="gspb_text gspb_text-id-gsbp-93ad77b ">• If RS485 communication does not work, check that you used the correct pins according to the model.<br/>• If communication still fails, verify the Modbus address and Baud rate values.<br/>• If control is not functioning, make sure the Unlock Password is still set to 2014.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>.</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Huawei SUN2000</title>
		<link>https://docs.qilowatt.eu/en/docs/huawei-sun2000/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 10:24:15 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/huawei-sun2000/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-720b811" class="gspb_heading gspb_heading-id-gsbp-720b811 ">Introduction</h2>

<div id="gspb_text-id-gsbp-00382c8" class="gspb_text gspb_text-id-gsbp-00382c8 ">Huawei SUN2000 inverters can be connected to the Qilowatt system via Modbus communication. This guide describes the required preparations, connections, and settings to ensure proper operation. </div>

<h2 id="gspb_heading-id-gsbp-deb9024" class="gspb_heading gspb_heading-id-gsbp-deb9024 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-004db6b" class="gspb_text gspb_text-id-gsbp-004db6b ">• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/">Creating a user account</a><br/>• Inverter, battery, and Smart Dongle firmware are updated<br/>• Smart Dongle removed (it interferes with Modbus communication)<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)</div>

<h2 id="gspb_heading-id-gsbp-0ca7007" class="gspb_heading gspb_heading-id-gsbp-0ca7007 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-5d22db7" class="gspb_heading gspb_heading-id-gsbp-5d22db7 ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-7c844ce" class="gspb_text gspb_text-id-gsbp-7c844ce ">• Update the firmware of the <strong>inverter, battery, and Smart Dongle</strong> before connecting.<br/>• Remove the <strong>Smart Dongle</strong>, as it interferes with Modbus communication and control will not work properly.</div>

<h3 id="gspb_heading-id-gsbp-0800f8b" class="gspb_heading gspb_heading-id-gsbp-0800f8b ">2. RS485 connections</h3>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-986838a" class="gspb_text gspb_text-id-gsbp-986838a ">Always refer to the installation manual of your specific model.<br/><br/><strong>Huawei SUN2000 M1 (10 kW) COM port:</strong><br/>• Pin 1 → RS485 A1<br/>• Pin 3 → RS485 B1<br/>• Pin 5 → GND (maandus)<br/>• Pin 7 → RS485 A2 (Smart Meter + battery)<br/>• Pin 9 → RS485 B2 (Smart Meter + battery)<br/>• Pin 13 → GND<br/><br/>For Qilowatt connection, use <strong>Pin 1 (A)</strong> and <strong>Pin 3 (B)</strong>.</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-f15cb81" id="gspb_image-id-gsbp-f15cb81"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-131806.png" data-src="" alt="" loading="lazy" width="333" height="324"></div>
</div>

<h3 id="gspb_heading-id-gsbp-08bb7b2" class="gspb_heading gspb_heading-id-gsbp-08bb7b2 ">3. Inverter settings</h3>

<div id="gspb_text-id-gsbp-437c8b6" class="gspb_text gspb_text-id-gsbp-437c8b6 ">• <strong>Modbus address:</strong> 1 (default)<br/>• <strong>Baud rate:</strong> 9600 (default)<br/><br/>If necessary, the Modbus address can be changed by Qilowatt support, but this is not required for standard connections.</div>

<h3 id="gspb_heading-id-gsbp-172aab8" class="gspb_heading gspb_heading-id-gsbp-172aab8 ">4. Operating modes</h3>

<div id="gspb_text-id-gsbp-58909a4" class="gspb_text gspb_text-id-gsbp-58909a4 ">• Set the inverter to <strong>Self-use</strong> mode.<br/>• In the FusionSolar app, disable all <strong>TOU (time-of-use) modes</strong> to avoid conflicts.</div>

<h3 id="gspb_heading-id-gsbp-5f4f97d" class="gspb_heading gspb_heading-id-gsbp-5f4f97d ">5. Why is a firmware update necessary?</h3>

<div id="gspb_text-id-gsbp-c0b9957" class="gspb_text gspb_text-id-gsbp-c0b9957 ">Qilowatt always uses the manufacturer’s latest Modbus protocol. If the inverter or battery firmware is not updated, control may not work correctly. </div>

<h2 id="gspb_heading-id-gsbp-77ad4c8" class="gspb_heading gspb_heading-id-gsbp-77ad4c8 ">Result</h2>

<div id="gspb_text-id-gsbp-442f5b0" class="gspb_text gspb_text-id-gsbp-442f5b0 ">The Huawei SUN2000 inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables inverter control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-ee891d3" class="gspb_heading gspb_heading-id-gsbp-ee891d3 ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-f2b0ca4" class="gspb_text gspb_text-id-gsbp-f2b0ca4 ">• If communication fails, check the RS485 connections (Pins 1 and 3 must be used correctly).<br/>• If the device does not respond to commands, ensure that the Smart Dongle has been removed.<br/>• If control does not work, verify the Modbus address and Baud rate values.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>.</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GoodWe ET / ET Plus</title>
		<link>https://docs.qilowatt.eu/en/docs/goodwe-et-et-plus/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 10:58:25 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/goodwe-et-et-plus/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-ec3d15b" class="gspb_heading gspb_heading-id-gsbp-ec3d15b ">Introduction</h2>

<div id="gspb_text-id-gsbp-5a0d939" class="gspb_text gspb_text-id-gsbp-5a0d939 ">GoodWe ET and ET Plus hybrid inverters can be connected to the Qilowatt system via Modbus communication. This guide explains the necessary preparations, RS485 wiring, inverter settings, and operating modes. </div>

<h2 id="gspb_heading-id-gsbp-44f305d" class="gspb_heading gspb_heading-id-gsbp-44f305d ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-0660ba2" class="gspb_text gspb_text-id-gsbp-0660ba2 ">• Inverter and battery firmware are updated (latest version must be used)<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)<br/>• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/">Creating a user account</a></div>

<h2 id="gspb_heading-id-gsbp-f45fa70" class="gspb_heading gspb_heading-id-gsbp-f45fa70 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-01271fd" class="gspb_heading gspb_heading-id-gsbp-01271fd ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-14d703d" class="gspb_text gspb_text-id-gsbp-14d703d ">• Update the <strong>inverter and battery firmware</strong> before connecting.<br/>• Ensure the device has the <strong>latest firmware</strong>, since Qilowatt always relies on the newest Modbus protocol.</div>

<h3 id="gspb_heading-id-gsbp-8bc6974" class="gspb_heading gspb_heading-id-gsbp-8bc6974 ">2. RS485 connections</h3>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-90831a5" class="gspb_text gspb_text-id-gsbp-90831a5 "><strong>GoodWe ET 5–10 kW hybrid inverter (COM port):</strong><br/>• Pin 1 → RS485 A1<br/>• Pin 2 → RS485 B1<br/>Use Pin 1 (A) and Pin 2 (B) to connect the Qilowatt device.  <br/><br/>Note: Before installation, make sure the device has a <strong>Data port.</strong> </div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-c958d97" id="gspb_image-id-gsbp-c958d97"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-135241.png" data-src="" alt="" loading="lazy" width="505" height="221"></div>
</div>

<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-5e5c4d9" class="gspb_text gspb_text-id-gsbp-5e5c4d9 "><strong>GoodWe ET 15–30 kW hybrid inverter (EMS port):</strong><br/>• Pin 1 → RS485 A<br/>• Pin 2 → RS485 B<br/>• Pin 4 → GND<br/>• Pin 5 → CAN_L<br/>• Pin 6 → CAN_H<br/>Use Pin 1 (A) and Pin 2 (B) to connect the Qilowatt device.  </div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-7b2d1dd" id="gspb_image-id-gsbp-7b2d1dd"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-123533-1.png" data-src="" alt="" loading="lazy" width="177" height="121"></div>
</div>

<h3 id="gspb_heading-id-gsbp-97cb393" class="gspb_heading gspb_heading-id-gsbp-97cb393 ">3. Inverter settings</h3>

<div id="gspb_text-id-gsbp-c20f659" class="gspb_text gspb_text-id-gsbp-c20f659 ">• <strong>Modbus address:</strong> 247 (default)<br/>• <strong>Baud rate:</strong> 9600 (default)<br/><br/>If needed, the Modbus address can be changed via the <strong>GoodWe SEMS</strong> or <strong>Solar-Go</strong> apps.</div>

<h3 id="gspb_heading-id-gsbp-903e541" class="gspb_heading gspb_heading-id-gsbp-903e541 ">4. Operating modes</h3>

<div id="gspb_text-id-gsbp-13d2d41" class="gspb_text gspb_text-id-gsbp-13d2d41 ">• Set the inverter to <strong>Self-use</strong> mode (in older systems called <em>General</em>).<br/>• Disable all modes that prevent external control:<br/><strong>TOU</strong> (time-of-use)<br/><strong>ECO</strong><br/><strong>Peak Shaving</strong><br/>All remote controls</div>

<h3 id="gspb_heading-id-gsbp-9342a3d" class="gspb_heading gspb_heading-id-gsbp-9342a3d ">5. Why is a firmware update necessary?</h3>

<div id="gspb_text-id-gsbp-e8f962b" class="gspb_text gspb_text-id-gsbp-e8f962b ">Qilowatt always uses the manufacturer’s latest Modbus protocol. If the inverter or battery firmware is not updated, control may not work correctly. </div>

<h2 id="gspb_heading-id-gsbp-bfa484e" class="gspb_heading gspb_heading-id-gsbp-bfa484e ">Result</h2>

<div id="gspb_text-id-gsbp-6eff2c6" class="gspb_text gspb_text-id-gsbp-6eff2c6 ">The GoodWe ET / ET Plus inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables inverter control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-0e81270" class="gspb_heading gspb_heading-id-gsbp-0e81270 ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-620919e" class="gspb_text gspb_text-id-gsbp-620919e ">• If communication does not work, check the RS485 connections and confirm that the port is available.<br/>• If control does not function, make sure the inverter is in Self-use mode and that all other modes (TOU, ECO, Peak Shaving) are disabled.<br/>• If the Modbus address is incorrect, change it using the SEMS or Solar-Go app.<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a>. </div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Solis S6</title>
		<link>https://docs.qilowatt.eu/en/docs/solis-s6/</link>
					<comments>https://docs.qilowatt.eu/en/docs/solis-s6/#respond</comments>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Thu, 18 Sep 2025 11:54:07 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/docs/solis-s6/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-04748af" class="gspb_heading gspb_heading-id-gsbp-04748af ">Introduction</h2>

<div id="gspb_text-id-gsbp-5590435" class="gspb_text gspb_text-id-gsbp-5590435 ">Solis S6 inverters can be connected to the Qilowatt system via Modbus communication. This guide explains the necessary preparations, RS485 wiring, inverter settings, and operating modes. </div>

<h2 id="gspb_heading-id-gsbp-13b65a4" class="gspb_heading gspb_heading-id-gsbp-13b65a4 ">Prerequisites</h2>

<div id="gspb_text-id-gsbp-df57208" class="gspb_text gspb_text-id-gsbp-df57208 ">• Inverter and battery firmware are updated (latest version must be used)<br/>• A Modbus module is available<br/>• Required tools and a communication cable (CAT5 or CAT6)<br/>• A Qilowatt account has been created and the app is ready for adding devices → <a href="https://docs.qilowatt.eu/en/docs/creating-a-user-account/">Creating a user account</a></div>

<h2 id="gspb_heading-id-gsbp-c43af74" class="gspb_heading gspb_heading-id-gsbp-c43af74 ">Step-by-step Guide</h2>

<h3 id="gspb_heading-id-gsbp-75a5de1" class="gspb_heading gspb_heading-id-gsbp-75a5de1 ">1. Preparation</h3>

<div id="gspb_text-id-gsbp-aee772c" class="gspb_text gspb_text-id-gsbp-aee772c ">• Update the <strong>inverter and battery firmware</strong> before connecting.<br/>• Ensure the device has the <strong>latest firmware</strong>, since Qilowatt always relies on the newest Modbus protocol.</div>

<h3 id="gspb_heading-id-gsbp-0566595" class="gspb_heading gspb_heading-id-gsbp-0566595 ">2. RS485 connections</h3>

<div id="gspb_text-id-gsbp-7dc33b9" class="gspb_text gspb_text-id-gsbp-7dc33b9 ">↓ Solis S6 3-10kW HV; Solis S6 8-15kW LV ↓</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-cbc7b93" id="gspb_image-id-gsbp-cbc7b93"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/photo_2025-11-10_13-28-31.jpg" data-src="" alt="" loading="lazy" width="955" height="602"></div>

<div id="gspb_text-id-gsbp-46e2044" class="gspb_text gspb_text-id-gsbp-46e2044 ">↓ Solis S6 12-20kW HV ↓</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-b833ab6" id="gspb_image-id-gsbp-b833ab6"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/photo_2025-11-10_13-28-26.jpg" data-src="" alt="" loading="lazy" width="1007" height="602"></div>

<div id="gspb_text-id-gsbp-2fe239a" class="gspb_text gspb_text-id-gsbp-2fe239a ">Solis S6 30-125 kW tuleb ühendada EMS porti, mitte RS485. (Juhul kui akuks on Dyness BF100, tuleb Qilowatti kontroller ühendada EMS porti, Aku BMS kaabel BMS porti ja aku EMS kaabel RS485 porti.) </div>

<h3 id="gspb_heading-id-gsbp-5a9fb0b" class="gspb_heading gspb_heading-id-gsbp-5a9fb0b ">3. Inverter firmware and SolisCloud settings</h3>

<div class="wp-block-greenshift-blocks-infobox gspb_infoBox gspb_infoBox-id-gsbp-3624e98" id="gspb_infoBox-id-gsbp-3624e98"><div class="gs-box notice_type icon_type"><div class="gs-box-icon"><svg x="0px" y="0px" viewBox="0 0 486.463 486.463"> <g> <g> <path d="M243.225,333.382c-13.6,0-25,11.4-25,25s11.4,25,25,25c13.1,0,25-11.4,24.4-24.4 C268.225,344.682,256.925,333.382,243.225,333.382z"></path> <path d="M474.625,421.982c15.7-27.1,15.8-59.4,0.2-86.4l-156.6-271.2c-15.5-27.3-43.5-43.5-74.9-43.5s-59.4,16.3-74.9,43.4 l-156.8,271.5c-15.6,27.3-15.5,59.8,0.3,86.9c15.6,26.8,43.5,42.9,74.7,42.9h312.8 C430.725,465.582,458.825,449.282,474.625,421.982z M440.625,402.382c-8.7,15-24.1,23.9-41.3,23.9h-312.8 c-17,0-32.3-8.7-40.8-23.4c-8.6-14.9-8.7-32.7-0.1-47.7l156.8-271.4c8.5-14.9,23.7-23.7,40.9-23.7c17.1,0,32.4,8.9,40.9,23.8 l156.7,271.4C449.325,369.882,449.225,387.482,440.625,402.382z"></path> <path d="M237.025,157.882c-11.9,3.4-19.3,14.2-19.3,27.3c0.6,7.9,1.1,15.9,1.7,23.8c1.7,30.1,3.4,59.6,5.1,89.7 c0.6,10.2,8.5,17.6,18.7,17.6c10.2,0,18.2-7.9,18.7-18.2c0-6.2,0-11.9,0.6-18.2c1.1-19.3,2.3-38.6,3.4-57.9 c0.6-12.5,1.7-25,2.3-37.5c0-4.5-0.6-8.5-2.3-12.5C260.825,160.782,248.925,155.082,237.025,157.882z"></path> </g> </g> </svg></div><div class="gs-box-text">
<p><strong>It is critical to update the inverter firmware after installation.</strong><br/>All firware components must be updated: DSP firmware, HMI firmware, Major firmware and all other inverter firmware components.</p>



<p><strong>All SolisCloud control functions must be turned OFF.</strong><br/>If any of the following functions are enabled in SolisCloud, it is not possible to control the inverter.</p>
</div></div></div>

<div id="gspb_text-id-gsbp-9d1a75c" class="gspb_text gspb_text-id-gsbp-9d1a75c "><strong>1)</strong> Solis AI, Peak Valley Arbitrage, Solis EMS and other automatic control functions must be turned OFF.</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-e55cf01" id="gspb_image-id-gsbp-e55cf01"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/7ee8933d-ff39-470a-9954-ed9a047db55c.png" data-src="" alt="" loading="lazy" width="440" height="97"></div>

<div id="gspb_text-id-gsbp-bc4f3cf" class="gspb_text gspb_text-id-gsbp-bc4f3cf "><strong>2) </strong>Storage Mode → Charge &amp; Discharge time slots must be turned OFF.</div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-8c87b4a" id="gspb_image-id-gsbp-8c87b4a"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/a717f2d7-a2a1-4512-9bb1-1f52a0b2bd01.png" data-src="" alt="" loading="lazy" width="448" height="58"></div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-135088d" id="gspb_image-id-gsbp-135088d"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/92b0e6d1-1d08-4e21-ab19-fb5ce6638e08.png" data-src="" alt="" loading="lazy" width="478" height="606"></div>

<div id="gspb_text-id-gsbp-6c01408" class="gspb_text gspb_text-id-gsbp-6c01408 "><strong>3)</strong> We recommend turning OFF Battery Saving, located under Battery Settings. This setting limits battery usage and reduces charging and discharging power. </div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-404f532" id="gspb_image-id-gsbp-404f532"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/b9e223e8-9843-4d6c-ac6c-fbdd0d530d55.png" data-src="" alt="" loading="lazy" width="380" height="53"></div>

<div id="gspb_text-id-gsbp-8fcea6c" class="gspb_text gspb_text-id-gsbp-8fcea6c "><strong>4)</strong> We recommend turning OFF Battery ECO Function, located under Settings -&gt; Function Settings. With some battery systems, it is not possible to charge the battery when it is empty and no PV production is available. </div>

<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-4dad293" id="gspb_image-id-gsbp-4dad293"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/561ceaf2-fc25-418f-83c3-c583957126ee.png" data-src="" alt="" loading="lazy" width="350" height="60"></div>

<h2 id="gspb_heading-id-gsbp-0addc18" class="gspb_heading gspb_heading-id-gsbp-0addc18 ">Result</h2>

<div id="gspb_text-id-gsbp-23ed942" class="gspb_text gspb_text-id-gsbp-23ed942 ">Solis S6 inverter is successfully configured and connected to the Qilowatt system. The module transmits data and enables inverter control and energy optimization. </div>

<h2 id="gspb_heading-id-gsbp-b394bfb" class="gspb_heading gspb_heading-id-gsbp-b394bfb ">If it Doesn&#8217;t Work</h2>

<div id="gspb_text-id-gsbp-66fe4d7" class="gspb_text gspb_text-id-gsbp-66fe4d7 ">• If communication does not work, check the RS485 connections<br/>• If the issue persists, contact our team: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a></div>

<p></p>
]]></content:encoded>
					
					<wfw:commentRss>https://docs.qilowatt.eu/en/docs/solis-s6/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
