<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>sol-ark &#8211; Qilowatt</title>
	<atom:link href="https://docs.qilowatt.eu/dtag/sol-ark/feed/" rel="self" type="application/rss+xml" />
	<link>https://docs.qilowatt.eu</link>
	<description></description>
	<lastBuildDate>Mon, 26 Oct 2026 03:11:42 +0000</lastBuildDate>
	<language>et</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://docs.qilowatt.eu/wp-content/uploads/2025/08/cropped-cropped-527027273_25002846699317774_491633004174988328_n-32x32.webp</url>
	<title>sol-ark &#8211; Qilowatt</title>
	<link>https://docs.qilowatt.eu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Deye / Sunsynk / Sol-Ark</title>
		<link>https://docs.qilowatt.eu/docs/deye-sunsynk-sol-ark/</link>
		
		<dc:creator><![CDATA[marko]]></dc:creator>
		<pubDate>Thu, 28 Aug 2025 17:37:08 +0000</pubDate>
				<guid isPermaLink="false">http://marko</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-54d638e" class="gspb_heading gspb_heading-id-gsbp-54d638e ">Sissejuhatus</h2>



<div id="gspb_text-id-gsbp-26d610d" class="gspb_text gspb_text-id-gsbp-26d610d ">Deye, Sunsynk ja Sol-Ark inverterid saab ühendada Qilowatt süsteemiga, kasutades Modbus R2 / R2 ETH moodulit. Järgnev juhend kirjeldab vajalikud seadistused, ühenduste loomist ning mooduli käivitamist. <br><br><strong>NB!</strong> Kui kasutad mitut Deye inverterit <strong>Master–Slave konfiguratsioonis</strong>, vaata lisaks juhendit → <a href="https://docs.qilowatt.eu/docs/deye-kaskaadlahendus/" data-type="docs" data-id="471"><strong>Deye kaskaadlahendus</strong>.</a></div>



<h2 id="gspb_heading-id-gsbp-b1f36d1" class="gspb_heading gspb_heading-id-gsbp-b1f36d1 ">Eeltingimused</h2>



<div id="gspb_text-id-gsbp-9e5501d" class="gspb_text gspb_text-id-gsbp-9e5501d ">• Inverteri tehnik on kontrollinud, et inverter töötab tõrgeteta<br>• Inverter suudab laadida akusid elektrivõrgust ning vajadusel müüa energiat võrku<br>• Aku maksimaalsed võimsuspiirangud on arvestatud<br>•  Olemas on Modbus R2 või R2 ETH moodul<br>• Vajalikud tööriistad ja sidekaabel (CAT5 või CAT6)</div>



<h2 id="gspb_heading-id-gsbp-43464ca" class="gspb_heading gspb_heading-id-gsbp-43464ca ">Samm-sammuline juhend</h2>



<h3 id="gspb_heading-id-gsbp-9106fc8" class="gspb_heading gspb_heading-id-gsbp-9106fc8 ">Inverteri seadistamine</h3>



<div id="gspb_text-id-gsbp-9a54607" class="gspb_text gspb_text-id-gsbp-9a54607 "><strong>1. </strong>Ava Deye inverteri menüü.<br><strong>2. </strong>Sea järgmised sätted:<br>• <strong>Modbus SN (aadress):</strong> 01<br>• <strong>Master/Slave:</strong> Slave<br><strong>• Modbus baudrate:</strong> 9600<br><strong>• Time of Use:</strong> aktiveeritud</div>



<h3 id="gspb_heading-id-gsbp-19e1e31" class="gspb_heading gspb_heading-id-gsbp-19e1e31 ">Mooduli paigaldamine</h3>



<div id="gspb_text-id-gsbp-0606274" class="gspb_text gspb_text-id-gsbp-0606274 "><strong>1.</strong> Paigalda <strong>MODBUS R2 või R2 ETH moodul</strong> vastavalt paigaldusjuhendile.<br><strong>2.</strong> Ühenda sidekaabel (CAT5 või CAT6) MODBUS mooduli RS485 pistiku A ja B klemmidest inverteri vastava pordiga.<br><br>⚠️ <strong>Oluline!</strong><br><strong>• </strong>Kui inverteri emaplaadil on <strong>DRM port</strong>:<br>Ühenda sidekaabel (CAT5 või CAT6) MODBUS mooduli RS485 pistiku A ja B klemmidest inverteri vastava pordiga.<br><strong>Deye LV (low voltage) puhul tuleb kasutada ainult BMS pordi kaudu ühendust!</strong><br><br>Ühenda kontroller moodul A ja B klemmid inverteri <strong>BMS pordi</strong> pistiku pinnidele: <strong><br>• </strong>Pin 1 → B<br><strong>• </strong>Pin 2 → A<br>Kui BMS port on juba aku poolt hõivatud, on vaja kasutada splitterit. Soeta <a href="https://qilowatt.eu/toode/splitter-deye-inverteri-juhtimiseks/" target="_blank" rel="noopener">Splitter Deye inverteri juhtimiseks.</a><br><br><strong>Deye HV (hig voltage) puhul võib kasutada RS485/Modbus pordi ühendus<br></strong><br>Ühenda MODBUS R2/R2 ETH moodul A ja B klemmid inverteri <strong>Modbus/RS485 pistiku</strong> pinnidele: <br><strong>• </strong>Pin 7 → A<br><strong>• </strong>Pin 8 → B</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-06837e0" id="gspb_image-id-gsbp-06837e0"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/08/528224762_1124649282925785_6576931699721567072_n.webp" data-src="" alt="" loading="lazy" width="768" height="654"/></div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-6e6d78e" id="gspb_image-id-gsbp-6e6d78e"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/08/photo_2026-10-26_13-22-24.jpg" data-src="" alt="" loading="lazy" width="1280" height="853"/></div>



<h3 id="gspb_heading-id-gsbp-ead0a41" class="gspb_heading gspb_heading-id-gsbp-ead0a41 ">Mooduli käivitamine</h3>



<div id="gspb_text-id-gsbp-832a9ec" class="gspb_text gspb_text-id-gsbp-832a9ec "><strong>1. </strong>Lülita sisse MODBUS R2 / R2 ETH mooduli kaitseautomaat või vinnasta sulavkaitse.<br><strong>2.</strong> Kontrolli, kas mooduli peal hakkas kiirelt vilkuma <strong>valge LED indikaator</strong>, <strong>R2</strong> <strong>ETH seadmel sisemine punane led indikaator.</strong> <br><strong>3. </strong>Ühenda moodul oma koduse WiFi võrguga, kasutades juhendit → <a href="https://docs.qilowatt.eu/docs/seadme-uhendamine-wifi-vorku/" data-type="docs" data-id="23">Seadme ühendamine WiFi võrku</a>.<br><strong>4. </strong>Paiguta moodul võimalusel kohta, kus on tugev WiFi signaal. R2 ETH seadmel ühenda võrgukaabel LAN porti peale kontrolleri seadistamist.<br><strong>5.</strong> <strong>R2 seadme puhul,</strong> vajadusel kasuta õigesti seadistatud WiFi võrgulaiendajat. </div>



<h2 id="gspb_heading-id-gsbp-fed8eac" class="gspb_heading gspb_heading-id-gsbp-fed8eac ">Tulemus</h2>



<div id="gspb_text-id-gsbp-c5c9df2" class="gspb_text gspb_text-id-gsbp-c5c9df2 ">Inverter on edukalt ühendatud Qilowatt süsteemiga. Modbus moodul edastab andmeid ning võimaldab seadmeid juhtida ja optimeerida.</div>



<h2 id="gspb_heading-id-gsbp-a223463" class="gspb_heading gspb_heading-id-gsbp-a223463 ">Kui ei õnnestu</h2>



<div id="gspb_text-id-gsbp-7b427dd" class="gspb_text gspb_text-id-gsbp-7b427dd ">• Kui LED-indikaator ei sütti, kontrolli ühendusi ja kaitset.<br>• Kui side ei tööta, veendu, et Modbus aadress ja baudrate on õigesti seadistatud.<br>• Kui moodul ei ühendu WiFi-sse, järgi juhendit <a href="https://docs.qilowatt.eu/docs/wifi-seadete-taaslahestamine/" data-type="docs" data-id="52">WiFi seadete taaslähtestamine</a>.<br>• Kui probleem püsib, võta ühendust meie tiimiga: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a> </div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
