<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>goodwe &#8211; Qilowatt</title>
	<atom:link href="https://docs.qilowatt.eu/dtag/goodwe/feed/" rel="self" type="application/rss+xml" />
	<link>https://docs.qilowatt.eu</link>
	<description></description>
	<lastBuildDate>Thu, 30 Oct 2025 09:48:37 +0000</lastBuildDate>
	<language>et</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://docs.qilowatt.eu/wp-content/uploads/2025/08/cropped-cropped-527027273_25002846699317774_491633004174988328_n-32x32.webp</url>
	<title>goodwe &#8211; Qilowatt</title>
	<link>https://docs.qilowatt.eu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GoodWe ET / ET Plus</title>
		<link>https://docs.qilowatt.eu/docs/goodwe-et-et-plus/</link>
		
		<dc:creator><![CDATA[Qilowatt Support]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 10:58:25 +0000</pubDate>
				<guid isPermaLink="false">https://docs.qilowatt.eu/?post_type=docs&#038;p=266</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<h2 id="gspb_heading-id-gsbp-ec3d15b" class="gspb_heading gspb_heading-id-gsbp-ec3d15b ">Sissejuhatus</h2>



<div id="gspb_text-id-gsbp-5a0d939" class="gspb_text gspb_text-id-gsbp-5a0d939 ">GoodWe ET ja ET Plus hübriidinverterid saab ühendada Qilowatt süsteemiga Modbus ühenduse kaudu. Järgnev juhend kirjeldab vajalikud ettevalmistused, ühendused ja seadistused.</div>



<h2 id="gspb_heading-id-gsbp-44f305d" class="gspb_heading gspb_heading-id-gsbp-44f305d ">Eeltingimused</h2>



<div id="gspb_text-id-gsbp-0660ba2" class="gspb_text gspb_text-id-gsbp-0660ba2 ">• Inverteri ja aku tarkvara on uuendatud (kasuta viimast firmware versiooni)<br>• Olemas on Modbus moodul<br>• Vajalikud tööriistad ja sidekaabel (CAT5 või CAT6)<br>• Qilowatt konto loodud ja äpp valmis seadmete lisamiseks → <a href="https://docs.qilowatt.eu/docs/kasutajakonto-loomine/">Kasutajakonto loomine</a></div>



<h2 id="gspb_heading-id-gsbp-f45fa70" class="gspb_heading gspb_heading-id-gsbp-f45fa70 ">Samm-sammuline juhend</h2>



<h3 id="gspb_heading-id-gsbp-01271fd" class="gspb_heading gspb_heading-id-gsbp-01271fd ">1. Ettevalmistus</h3>



<div id="gspb_text-id-gsbp-14d703d" class="gspb_text gspb_text-id-gsbp-14d703d ">• Uuenda <strong>inverteri ja aku tarkvara</strong> enne ühendamist.<br>• Veendu, et seadmel oleks <strong>viimane firmware</strong>, kuna Qilowatt tugineb alati tootja uusimale Modbus protokollile.</div>



<h3 id="gspb_heading-id-gsbp-8bc6974" class="gspb_heading gspb_heading-id-gsbp-8bc6974 ">2. RS485 ühendused</h3>



<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-90831a5" class="gspb_text gspb_text-id-gsbp-90831a5 "><strong>GoodWe ET 5–10 kW hübriidinverter (COM port):</strong><br>• Pin 1 → RS485 A1<br>• Pin 2 → RS485 B1<br>Qilowatt seadme ühendamiseks kasuta Pin 1 (A) ja Pin 2 (B).<br><br>NB! Enne paigaldust veendu, et seadmel oleks olemas <strong>Data pistik</strong>.</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-c958d97" id="gspb_image-id-gsbp-c958d97"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-135241.png" data-src="" alt="" loading="lazy" width="505" height="221"/></div>
</div>



<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex">
<div id="gspb_text-id-gsbp-5e5c4d9" class="gspb_text gspb_text-id-gsbp-5e5c4d9 "><strong>GoodWe ET 15–30 kW hübriidinverter (EMS port):</strong><br>• Pin 1 → RS485 A<br>• Pin 2 → RS485 B<br>• Pin 4 → GND<br>• Pin 5 → CAN_L<br>• Pin 6 → CAN_H<br>Qilowatt seadme ühendamiseks kasuta Pin 1 (A) ja Pin 2 (B).</div>



<div class="wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-7b2d1dd" id="gspb_image-id-gsbp-7b2d1dd"><img decoding="async" src="https://docs.qilowatt.eu/wp-content/uploads/2025/09/Kuvatommis-2025-09-02-123533-1.png" data-src="" alt="" loading="lazy" width="177" height="121"/></div>
</div>



<h3 id="gspb_heading-id-gsbp-97cb393" class="gspb_heading gspb_heading-id-gsbp-97cb393 ">3. Inverteri seaded</h3>



<div id="gspb_text-id-gsbp-c20f659" class="gspb_text gspb_text-id-gsbp-c20f659 ">• <strong>Modbus aadress:</strong> 247 (vaikimisi)<br>• <strong>Baud rate:</strong> 9600 (vaikimisi)<br><br>Vajadusel saab Modbus aadressi muuta rakenduste kaudu: <strong>GoodWe SEMS</strong> või <strong>Solar-Go</strong>.</div>



<h3 id="gspb_heading-id-gsbp-903e541" class="gspb_heading gspb_heading-id-gsbp-903e541 ">4. Töötamisrežiimid</h3>



<div id="gspb_text-id-gsbp-13d2d41" class="gspb_text gspb_text-id-gsbp-13d2d41 ">• Seadista inverter <strong>Self-use</strong> režiimi (vanemates süsteemides nimega <em>General</em>).<br>• Lülita välja kõik režiimid, mis takistavad juhtimist:<br><strong>TOU</strong> (ajapõhised režiimid)<br><strong>ECO</strong><br><strong>Peak Shaving</strong><br>Kõik kaugjuhtimised</div>



<h3 id="gspb_heading-id-gsbp-9342a3d" class="gspb_heading gspb_heading-id-gsbp-9342a3d ">5. Miks tarkvarauuendus on vajalik?</h3>



<div id="gspb_text-id-gsbp-e8f962b" class="gspb_text gspb_text-id-gsbp-e8f962b ">Qilowatt kasutab alati tootja uusimat Modbus protokolli. Kui inverteri või aku tarkvara pole uuendatud, ei pruugi juhtimine toimida õigesti.</div>



<h2 id="gspb_heading-id-gsbp-bfa484e" class="gspb_heading gspb_heading-id-gsbp-bfa484e ">Tulemus</h2>



<div id="gspb_text-id-gsbp-6eff2c6" class="gspb_text gspb_text-id-gsbp-6eff2c6 ">GoodWe ET / ET Plus inverter on edukalt seadistatud ja ühendatud Qilowatt süsteemiga. Moodul edastab andmeid ning võimaldab inverterit juhtida ja energiakasutust optimeerida.</div>



<h2 id="gspb_heading-id-gsbp-0e81270" class="gspb_heading gspb_heading-id-gsbp-0e81270 ">Kui ei õnnestu</h2>



<div id="gspb_text-id-gsbp-620919e" class="gspb_text gspb_text-id-gsbp-620919e ">• Kui side ei tööta, kontrolli RS485 ühendusi ja pistiku olemasolu.<br>• Kui juhtimine ei toimi, veendu, et inverter on Self-use režiimis ja kõik muud režiimid (TOU, ECO, Peak Shaving) on välja lülitatud.<br>• Kui Modbus aadress ei sobi, muuda see SEMS või Solar-Go rakenduse kaudu.<br>• Kui probleem püsib, võta ühendust meie tiimiga: <a href="mailto:support@qilowatt.eu">support@qilowatt.eu</a> </div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
